| Beamline Website |
http://pfweis.kek.jp/~protein/BeamLine/NW12/nw12.html |
| Owner/Operator |
Structural Biology Research Center |
| Operational (general use) |
yes |
| %Time available (general use) |
. |
| Beamline Schedule |
http://pfweis.kek.jp/~protein/index_eng.html |
| Experiments |
Macromolecular crystallography |
| Source |
In-vacuum Undulator (with taper option) |
| Ring Current(mA) |
. |
| Average Beam Lifetime |
. |
| Spot Size |
. |
| Optics |
Numerical link type Si(111) double crystal monochromator. Mirror 1: collimating, Rh-coated silicon single crystal, flat shaped. Mirror 2: focusing, Rh-coated silicon single crystal, toroidal.
|
| Flux |
2 x 1011@6.5 GeV, 40 mA, 1.0 A |
| Flux Details |
. |
| Wavelength Min (Å) |
0.7 |
| Wavelength Max (Å) |
1.9 |
| Monochromator |
Numerical link type double crystal monochromator, direct water cooling using micro-channel (1st crystal), indirect water cooling (2nd crystal)
|
| Crystal type |
Si(111) |
| Mirrors |
Collimating mirror: Rhodium coated silicon single crystal (Flat), Focusing mirror:Rhodium coated silicon single crystal (Troidal)
|
| Mirror Cutoff |
. |
| Special Capabilities |
sample exchange robot |
| Other Instrumentation |
Fluorescence detector : SSD |
| Goniometer |
. |
| Pin Length |
. |
| Restrictions |
. |
| xtal-detector Distance |
60 - 1000 mm |
| Detector |
ADSC Q210 CCD |
| Detector Details |
. |
| 2theta range |
. |
| Cryo Capability |
nitrogen gas flow around 95K |
| Lab Facilities |
3 protein crystallography labs, cold room |
| Biohazard |
. |
| Software |
HKL2000, DPS/Mosflm/Scala |
| Hardware |
4 PC Workstations (Linux), 2 PC Windows |
| Backup Devices |
IEEE1394 interface |
|
|